亚洲图片欧美色图,久久福利,免费视频成人片在线观看,一本到高清无码不卡视频网站

Medical

Cellulose Acetate (CA) Membrane

Cellulose-Acetate-(CA)-Membrane-Cobetter.png


Cobetter Cellulose Acetate (CA) Filtration Membrane is unsupported, hydrophilic membrane. Composed of pure cellulose acetate, the membrane has dimensional stability and naturally low protein binding.


This provides higher throughput than competitor offerings and reduces the amount of filter changes needed during filtration of proteinaceous solutions. It is ideal for use in filtration applications where maximal recovery of protein is critical. Due to its low binding capability, CA membrane is a good choice for sterile filtration of aqueous solutions,such as buffers,serum and cell culture media.


In addition,CA membrane combines good chemical resistance ranging from PH4-8, high flow rates and thermal stability, therefore is ideally suitable for pressure filtration devices, like syringe filters, disposable vacuum filter funnels etc.


Besides general filtration,Cellulose acetate (CA) membrane can be also made into sterile gridded filters,which is widely used for colony counting in microbiology testing. CA membrane has very pure and nature characteristic,so it features outstanding recovery rate for microorganisms and absolute filtration efficiency.


Cobetter CA Membrane is available in roll form, as well as in sheets and disks that can be customized to meet your application and size requirements. 



Features & Benefits

Superior strength to withstand aggressive handling or use with automated equipment without breaking or tearing

? Low protein binding minimizes retention of proteins in solution

? Low extractables ensure tests to be clean with consistent results

? Lot-to-lot consistency ensures consistent flow and diffusion rates for dependable results every time

? Non-lysing of cells prevents contamination of critical solutions

 


Typical Applications

? Protein and enzyme filtration

? Biological fluid sterilization

? Sterile filtration of aqueous solutions,nutrient media,buffers and serum;

? Colony counting,particle testing,microscopy and sterility testing.

? Prefiltration of plasma fractions and vaccines


Filtration-Unit.pngGridded-membrane-filter.pngSterile-syringe-filter.png
Filtration UnitGridded Membrane FilterSterile Syringe Filter 



Product Characteristics

Wettability: Hydrophilic

Sterilization method: Autocalvable at 121℃ or 134℃, gamma radiation 25 kgy, dry heat and Ethylene oxide.




Typical Performance Characteristics(*0.2μm Unsupported)

Meets USP<88>, for class VI-121℃ plastic

  Thickness  Water Flow Rate / s @30kPa*50ml*12.686cm2

    Water Bubble Point

  90-120 μm   20 - 22s

    ≥330kpa


Available Pore Size

0.22μm  ,  0.45μm 


 

Available Format
Membrane Discs,  Roll,  Sheet,  Disc,  Customization.




For technical data sheet or application inquiry, you are more than welcome to contact our sales representative by sales@cobetterfilter.com or leave a message