亚洲图片欧美色图,久久福利,免费视频成人片在线观看,一本到高清无码不卡视频网站

Vent Filter Housing(H-VCF)

Cobetter H-VCF Vent Filter Housing is mainly used in pharmaceutical applications and food and beverage industries to sterilize the air or gas. Housing gas is first separated inside and then goes through the housing to outside, thus outside organisms and particles do not enter the filter housing. Vent housing structure is simple and easy to operate. Its constructed of 316L or 304 stainless steel and mechanical polished or electro-polished.


Step1

Calculate the maximum gas thank volume

    V=| V (liquid inlet) -V (liquid outlet) | max

Step2

Confirm sterilized membrane filter and its pore size according to application


Step3

According to △(Design negative pressure of tank ) and V and sterilize membrane filter types(as follows) to choose correct filter specification



GPF-P5 inch10 inch20 inch30 inch
△P=1KPa6m3/h12m3/h24m3/h36m3/h
△P=2KPa12m3/h23m3/h40m3/h61m3/h




Vent Housing wth Jacket(Avoid Condensation)

Composed of vent housing, heating jacket, jacket protection and constant tempearture electric-heathing device

  • Heat can dry wet filter cartridges and ensure filter rate
  • Bacteria cannot survive under high temperature
  • Advanced heat on system
  • Eibow design - eliminates large particles outside to avoid entering the vent housing and protects the filter carridges
  • Specification
  • Performance
  • Ordering Information
Contact Form
Corporate name* Department*
Name*
E-mail address*
Tel
Address
Leaving a message