TefloGas Filter Cartridges
Hydrophobic PTFE Membrane · Sterilizing Grade

TefloGas Filter Cartridges are composed of a hydrophobic PTFE membrane and a thick thermal-resistance polypropylene core. They are characterized by a high filtration area and non-metallic ion release and are easy to clean when compared to filters with a stainless steel core. As a result, they are highly recommended for air and gas sterile filtration of biological liquids and fermentation and pharmaceutical industries.



Features and Benefits

  • Inherently hydrophobic

  • Exceptionally high flow rates with low pressure drops



Quality Standards:

  • Bacterial quantitative retention of 107 CFU/cm2 Brevundimonas Diminuta (ATCC 19146) according to ASTM F838 methodology .
  • 100% Integrity testing in manufacturing .
  • Each filter is fully traceable with unique serial number .
  • Manufactured in a facility which adheres to ISO 9001: 2015 Practices .

  • Full Regulatory Compliance with following :
    ? Bacterial Endotoxin : Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined by Limulus Amebcyte Lysate (LAL),USP<85>.

    ? Non-fiber Releasing : Component materials meet the criteria for a "Non-fiber-releasing filter" as defined in 21 CFR 210.3(b)(6).

    ? Component Material Toxicity :Meet the requirement of USP <87> In Vitro Cytotoxicity Test ; Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121℃ plastics

    ? TOC/Conductivity at 25 ℃:Autoclaved filter effluent meet the USP<643> for Total Organic Carbon and USP<645> for

    ? Water Conductivity per WFI requirements after a UPW flush of specified volume .

    ? Particle Shedding : Autoclaved filter effluent meet the USP<788>for large volume Injections .

    ? Indirect Food Additive:All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182 , and EU framework regulation [1935/2004/EC].



Typical Applications

  • Aseptic Packaging

  • Compressed Air and Nitrogen Gas Sterilization

  • Corrosive Gases Sterilization

  • Vent Filtration



  • Specification
  • Performance
  • Ordering Information

Materials of Construction


Filter Media

Hydrophobic PTFE Membrane

Support

Polypropylene

Core/Cage/End Caps

Polypropylene




Operating Conditions


Max. Operating Pressure

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Max. Differential Pressure

Forward

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Reverse

3.0 bar (44 psi) at 25 °C

1.0 bar (15 psi) at 80 °C

Effective Filtration Area0.68m2 / Φ 68-10 inch




Sterilization


Inline Steam Sterilization

Up to 100 forward cycles and 50 reverse cycles 

(145℃ for 30min <0.3bar per cycle)

Autoclaveup to 400 cycles (130°C for 30min for every cycle)

 


Integrity Test Data


GPFMP

Bubble Point

BP: ≥ 0.1 MPa (60%/40%IPA/Water)

Diffusion FlowDF: ≤ 24ml/min/10''cartridge @ 80KPa (60%/40%IPA/Water)

Water Intrusion Test

WFT : ≤0.75ml/min/10''cartridge @ 0.25MPa

 

GPFP

Bubble Point

BP: ≥ 0.11 MPa (60%/40%IPA/Water)

Diffusion FlowDF: ≤ 16ml/min/10''cartridge @ 80KPa (60%/40%IPA/Water)

Water Intrusion Test

WFT : ≤0.38ml/min/10''cartridge @ 0.25MPa

 





 



Flow Rate Characteristics



Ordering Infomation


TypeRemoval RatingsEnd CapNominal LengthSeal MaterialIndustry

GPFMP

GPFP






0001=0.01μm

0022=0.22μm







HSF=226 /Fin (PBT Insert)

HSC=226 /Flat (PBT Insert)

HTF=222 /Fin (PBT Insert)

HTC=222 /Flat (PBT Insert)

DOE=Double Open End


05= 5"

10=10"

20=20"

30=30"

40=40"


S=Silicone

E=EPDM

V=Viton

P=PFA/Viton


P=Pharmaceutical